It is crucial that any spherical aberration are removed by way of pinhole.  The laser spot is passed through a pinhole, which acts to expand the beam. This expansion creates a patter known as an [http://en.wikipedia.org/wiki/Airy_disk Airy pattern].  To correctly remove the spherical aberrations, the beam must be expanded such that the only the first ring is sent through the second lens, and the rest is blocked off.  To determine the proper pinhole size for the design, [[Huygens Principle for a Planar Source|the following analysis was performed]].
 
It is crucial that any spherical aberration are removed by way of pinhole.  The laser spot is passed through a pinhole, which acts to expand the beam. This expansion creates a patter known as an [http://en.wikipedia.org/wiki/Airy_disk Airy pattern].  To correctly remove the spherical aberrations, the beam must be expanded such that the only the first ring is sent through the second lens, and the rest is blocked off.  To determine the proper pinhole size for the design, [[Huygens Principle for a Planar Source|the following analysis was performed]].
  
== Camera Calibration ==
+
== Design of a mounting device for diamond surface analysis ==
Analysis of videos taken of the vibration of the diamond wafer can lead to information about both the frequency and the amplitude of vibrationTo perform simultaneous measurements of both parameters, a precise camera calibration was necessary.
+
 
 +
During the last test as [http://www.chess.cornell.edu/ CHESS] it was determined that the wire mount was not suitable for diamond analysis because the rocking curve was skewed by the high vibrational frequency of the diamond-wire system.  In order to perform the surface analysis, a new mounting device is in development. 
 +
[[Image:Mylar mount.jpg|center|Mount which will be used at the next run at CHESS]]
 +
This device is composed of two stretched mylar sheets with each sheet attached to one half of the mount. The diamond will be placed between the sheetsThis advantage of this type of mount is that it will create very little stress on the diamond sample, preventing the sample from warping. This type of mount cannot be used in the final beam path at JLab because of the high temperatures on the vacuum chamber (~500 \degree C)

Revision as of 04:39, 21 December 2010

Abstract

All atoms are made up of protons and neutrons, which are in turn comprised of quarks. The particles “gluing” the quarks together are known as gluons. The interaction of quarks and gluons is still not entirely understood, specifically how they are confined in the nucleus such that lone quarks are never seen. The nuclear physics group at the University of Connecticut is part of the GlueX Experiment, which hopes to probe directly the gluon bond and understand its mechanical properties. The probe used by GlueX is a high energy (small wavelength), polarized photon (particle of light) generated by a technique known as coherent bremsstrahlung . This technique involves radiation of photons as a high energy electron beam passes through a carefully oriented diamond wafer. Because of the potential for contamination, it is necessary to suspend the diamond wafer rather than mount on a ridged mount. The diamond is currently suspended on thin tungsten wires. Proper orientation ensures a high degree of polarization, which requires stable mounting of the diamond. The goal of my research is to investigate the mechanical properties of the mount and eliminate the possibility of vibration of the crystal.

The pupose of this page is to describe the work being done on the development of a system to analyze these vibrations. Two different techniques will be used to determine the amplitude and frequency of these vibrations. First, a direct imaging technique will be used. A Michelson interferometer will also be constructed, and will be used in not only the vibrational research, but also in the analysis of the diamond surface structure.

Construction

Parts List

The following is a lis of the parts used in the construction of the inerferometer, along with a brief descripton of the parts.

Category Item Description
Beam Splitter Beam Splitter Cube (2cm)3, AR, 400-700nm
Kinematic Platform Mount (2in)2
Prism Clamp Large clamping arm
Camera Casio Ex-F1
Mirrors Protected Silver Mirror 25.4mm Dia., R≈98%
Mirror Holder Standard 1" holder
Kinematic Mirror Mount Adjustable Kinematic mount for 1" holder
Light Source 532nm Green laser Module 5mW, 5mm spot size, <1.4 mrad div.
Kinematic V-Mount Small Mount with Attached Clamping Arm
Beam Expander/Spatial Filter Pinhole 5μm, 10μm, 15μm, and 20μm pinholes
Pinhole Holder 1/2" and 1" standard holder
Small Plano-Convex Lens f=50mm, 12.7mm Dia., AR coating
Lens Holders Holder for 1/2" and 1" optics lenses
Large Plano-Convex Lens f=150mm, 25.4mm Dia., AR coating
Translation Stages Small Linear Translation Stage 1 dimension translation stage
3-Axis Linear Translation Stage 3 dimension translation stage
Common Mechanics Posts 3/4" and 1" high posts, 1/2" Dia.
Post Holders 1" high post holders
Safety Equipment Laser Safety Glasses Green and Blue laser beam protection


Estimating Camera Sensitivity

Originally the parts list called for a 1mW laser. There was a concern, however, that this laser would not be powerful enough to produce interferograms. It is critical to understand the sensitivity of the camera to light from the interferometer, given the high intended image acquisition speed. The camera purchased for this setup, Casio EX-F1, has a movie frame rate capability of 1200 Hz. The following information allows an order of magnitude estimate of the sensitivity. (The camera uses a CMOS sensor. Note that lx=lm·m2)

  • a sample CMOS chip, Micron's MT9P401, has sensitivity of 1.4 V/lx·s and supply voltage of 2.8 V yielding 2 lx·s of light energy to saturation.
  • Light intensity conversion - 320 lm/W given:
    • a 100 W incandescent light bulb is measured to have the perceived intensity of about 1600 lm
    • a rough figure of efficiency for a 100 W is 5%

Using these conversions, the sensor pixels saturate at 6.3×10-3 W·m2·s. At 1200 Hz acquisition rate, assuming 100% duty cycle, the saturation figure is 5.2×10-6 W·m.

Now, let us assume that only about 5% of 1 mW laser light reaches the sensor due to cleanup in the beam expander and the light transmitted through the diamond. If the light is expanded to a 2 cm diameter beam, the beam at the sensor is rated at 1.6×10-8 W·m2

The two order of magnitude shortfall means that very little of the dynamic range of the sensor will be used, leading to a low signal to noise ratio. For this reason, a 5mW laser was chosen over a 1mW.

Choosing a pinhole

It is crucial that any spherical aberration are removed by way of pinhole. The laser spot is passed through a pinhole, which acts to expand the beam. This expansion creates a patter known as an Airy pattern. To correctly remove the spherical aberrations, the beam must be expanded such that the only the first ring is sent through the second lens, and the rest is blocked off. To determine the proper pinhole size for the design, the following analysis was performed.

Design of a mounting device for diamond surface analysis

During the last test as CHESS it was determined that the wire mount was not suitable for diamond analysis because the rocking curve was skewed by the high vibrational frequency of the diamond-wire system. In order to perform the surface analysis, a new mounting device is in development.

Mount which will be used at the next run at CHESS

This device is composed of two stretched mylar sheets with each sheet attached to one half of the mount. The diamond will be placed between the sheets. This advantage of this type of mount is that it will create very little stress on the diamond sample, preventing the sample from warping. This type of mount cannot be used in the final beam path at JLab because of the high temperatures on the vacuum chamber (~500 \degree C)