Operation of CODA Run Control - Fall 2015

From UConn PAN
Revision as of 20:46, 3 November 2015 by Jonesrt (talk | contribs)
Jump to navigation Jump to search

A new VME crate has been loaned to us by JLab. This is a non-VXI crate, and it came with a single CAEN V792 integrating ADC module instead of the fADC250 that we were using for tests in 2013-2014. These changes have required us to go back to the start and reconfigure a CODA daq runtime that works with the fall 2015 setup. Some things have not changed relative to what is described in Procedure for Operation of CODA Run Control - Fall 2013.

  1. the ROC is still at 137.99.19.12 (halldtrg5.phys.uconn.edu, also called guest2.phys.uconn.edu)
  2. the userid for running CODA is still halld (see R. Jones for pw)
  3. we are still running CODA version 2.6.1 (see /usr/local/coda/* for version info)
  4. we are still running the "micro_test" configuration in the msql database
    • one readout controller called TROC5
    • one event builder called EB5
    • one event recorder called ER5
  5. we are still configured to write output data to /home/halld/data which is mounted on /nfs/direct/annex2/TAGM-tests on the cluster